Jilong Indonesia

Jilong 300T

  • All-Metal construction
  • 6-Motor, core alignment
  • G654E fiber compatible
  • 3D surround dual heating slots 10s heating (fast mode)
  • Tool-Less disassembly SOC holder
  • 9000mAh Li-ion battery 500 splice+heat cycles per charge

Specifications

Specifications
Splice Method : Core Alignment
Applicable Fibers : SM(TTU-T G.652&G.657)/ MM(ITU-T G.651)/CS(ITU-T G.654)/DS(TU-T G.653)/ NZDS(TU-T G.655)
Compatible Fiber/Cable : 0.25~3.0mm/Drop Cable
Fiber Holder : Replaceable Universal Holder
Fiber Diameter : Cladding:80-150μm,Coating:100~1000μm
Fiber Cleave Length : 8~16 mm
Splice mode : Max 128 groups
Typical Splice Loss : SM:0.02dB/MM:0.01dB/CS:0.03dB/DS:0.04dB/NZDS:0.04dB/G.657:0.02dB ★①
Return Loss : >>60dB
Splicing Time : 6s(SM G652 QuickMode)
Estimated Splice Loss : Available
Heating Time : 10s(SM G652 250μm 40mm heat shrink tubing Fast mode)user adjustable
Protection Sleeve Length : 20mm, 30mm, 40mm, 50mm, 60mm
Heat Programs: Max 32 groups
Battery : 9000mAh Lithium battery, approx. 500 splice & heat cycles per charge ★②
Electrode Life : Approx. 5000 discharges ★③
Auto-start : Splicing / Heating
Automatic Fiber Identification : Supported
Automatic ARC Identification : Automatic calibration based on ambient temperature and air pressure
Results Storage : 10,000 splice records or 2,000 splice images
Tension Test : 1.96~2.25N
Operating Condition : Altitude: 0~5000m, 0~95% relative humidity, -20~50°C, Max Wind 15m/s
Storage Condition : 0~95% relative humidity, -20~60°C
Display : 5.0 inch High-definition LCD display
Fiber Magnification : X,Y,XY,X/Y:320x magnification
Power Supply : AC Input 100-240V, DC Input 9-14V
Terminal : USB2.0
Weight : 2.367kg(without battery)/2.9kg(with battery)
Size : 167Hx 147Wx 166D mm (including protective case)
★All-Metal Material: Excluding the battery, metal components account for over 65%+ of the weight.
★500 Splice + Heat Cycles on Full Charge: Results obtained in a room temperatureenvironment using 0.25mm fiber and 40mm sleeves; results are largely influenced bybattery status and operation.
★Cleaver Workstation: The workstation must be purchased separately.
① Results are tested using standard fibers according to ITU-T and IEC standard truncation methods; loss varies due to environment and fiber characteristics.
② Results obtained in a room temperature environment; largely influenced by battery status and operating environment.
③ Electrode life varies due to environment, fiber types, and splicing modes.